BRMWX - AQUADEX, 9002W118

  • MSDS: BRMWX
  • Manufacturer: DEXTER CORP
  • Product Name: AQUADEX, 9002W118
  • National Stock Number: 8010-00N039934
Product Identification

Product ID:AQUADEX, 9002W118
MSDS Date:01/10/1992
FSC:8010
NIIN:00N039934
MSDS Number: BRMWX

Responsible Party
DEXTER CORP
31500 HAYMAN
HAYWARD, CA 94544
US

Emergency Phone: 510-471-7171;510-791-1961

Info Phone: 510-471-7171;510-791-1961

Preparer: D. HECKMAN

Cage: 57294

Contractor
DIVERSITY WATER TECHNOLOGIES INC
200 CHAGRIN FALLS, OH 44022 US

Telephone: 216-247-5000

Cage: 57294

Ingredients

0.3 @ 20C.

CAS: 872-50-4

RTECS: UY5790000

Fraction By Weight: <10%

OSHA PEL N/K

ACGIH TLV: N/K


0.6 @ 20C.

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: <10%

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM; 9293


0.01 @ 20C.

CAS: 84-74-2

RTECS: TI0875000

Fraction By Weight: <10%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:OVEREXPOSURE BY INHALATION MAY
CAUSE IRRITATION OF THE RESPIRATORY TRACT, HEADACHE, DIZZINESS OR
DROWSINESS. SKIN/EYE:IRRITANT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:ANIMAL STUDIES CLEARLY DEMONSTRATED
DOSE-RELATED ADVERSE EFFECTS ON THE CNS, HEMATOPOIETIC TISSUE,
BLOOD, KIDNEYS, AND LIVER ASSOCIATED WITH THE ADMINISTRATION OF
ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE ) (EXTRACTED FROM DHHS
(NIOSH) PUBLICATION NO. 90-118) .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE. EYE:FLUSH IMMEDIATELY WITH LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SKIN:REMOVE CONTAMINTED
CLOTHING AND WASH SKIN WITH SOAP & WATER. INGEST:DRINK WATER. IF
NECESSAR Y, CALL MD FOR ANY OF THESE CONDITIONS.

Fire Fighting

Flash Point Method:SCC
Flash Point:205F,96C
Lower Limits:0.47%
Extinguishing Media:USE WATER FOG, FOAM, DRY CHEMICAL OR CARBON
DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:AVOID BREATHING VAPORS, VENTILATE AREA, AND
REMOVE WITH INERT ABSORBANT AND NON-SPARKING TOOLS. REFER TO
INGREDIENT SECTION BEFORE ATTEMPTING CLEAN UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT TAKE INTERNALLY. MAKE SURE DRUM
IS COMPLETELY EMPTY BEFORE ATTEMPTING TO WELD OR BRAZE. THE DRUM
SHOULD BE INDUSTRIALLY CLEANED PRIOR TO REUSE.
Other Precautions:DO NOT FLAME CUT, BRAZE, OR WELD WITHOUT NIOSH/MSHA
APPROVED RESPIRATOR OR APPROPRIATE VENTILATION.

Exposure Controls

Respiratory Protection:ALL RESPS MUST BE NIOSH/MSHA APPROVED. WHERE GEN
DILUTION OR LOC EXHST FAILS TO ADEQ DILUTE TWA/PEL OF THE MATL,
THEN RESP PROT SHOULD BE AS FOLLOWS:I/A/W 29CFR 1910.134, USE AN
AIR LINE TYPE RESP OR HOOD FOR ENCLSD/CONFINED AREAS. (SUPDAT)
Ventilation:PROVIDE GENERAL DILUTION/LOC EXHST VENT TO KEEP TWA AND LEL
BELOW ACCEPTABLE LIMITS & TO REMOVE DECOMP PRODUCTS.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
RESP PROT:AIR PURIFYING RESPIRATORS MAY BE USED FOR OTHER AREAS.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:9.828

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FUMES MAY CONTAIN CARBON MONOXIDE &
OXIDES OF NITROGEN. MAY PRODUCE HAZARDOUS FUMES WHEN HEATED TO
DECOMP AS IN WELDING.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.